Stainless steel IP67 single-point load cell
Suitable for weighing equipment like platform and belt scales.
Maximum platform size: 400 x 400 mm
High accuracy.
High reliability.
Current calibrated (SC-option).
Model: B6N Class: C3
Resistance:
Input - 384Ω ± 4Ω Output - 350Ω ± 3.5Ω
Brand: Zemic
Mfg: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
FM1020 Load Cell (FM1020)
Used in PLC Applications, Precision Balance, Analytical balance, low capacity scale
BM24R (BM24R)
• Stainless steel IP68 low profile load cell
• Hermetically sealed
• Suitable for hopper, platform and pallet scales
• Integrated static overload protection up to 13t
B6N Loadcell (B6N)
Stainless steel IP67 single-point load cell
Suitable for weighing equipment like platform and belt scales.
Maximum platform size: 400 x 400 mm
High accuracy.
High reliability.
Current calibrated (SC-option).
Model: B6N Class: C3
Resistance:
Input - 384Ω ± 4Ω Output - 350Ω ± 3.5Ω
Brand: Zemic
Mfg: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
Available Models:
Capacity Accuracy Full Article Description 8kg C3/C4 B6N-C3/C4-8kg-1B6 10kg C3/C4 B6N-C3/C4-10kg-1B6 15kg C3/C4 B6N-C3/C4-15kg-1B6 20kg C3/C4 B6N-C3/C4-20kg-1B6 30kg C3/C4 B6N-C3/C4-30kg-1B6 50kg C3 B6N-C3-50kg 75kg C3 B6N-C3-75kg 100kg C3 B6N-C3-100kg 150kg C3 B6N-C3-150kg 200kg C3 B6N-C3-200kg
Technical Specifications of FM1263
Accuracy Class OIML R60 C3, OIML R60 C4 Output Sensitivity ( FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) kg 8, 10, 15, 20, 30, 50, 75, 100, 150, 200 Max. Number of Load Cell Intervals nLC 3000, 4000 Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000 Combined Error %FS ≤± 0.023; ≤± 0.018 Creep Error (30 minutes) %FS ≤± 0.016; ≤± 0.012 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015; ≤± 0.010 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011; ≤± 0.009 Zero balance %FS ≤± 1.5 Safe overload %FS 150 Ultimate Overload %FS 300 Maximum Deflection mm 0.1t – 0.2t: 0.3 0.5t – 5t: ~ 1.2 10t: 0.8 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 384 ± 4 Output Resistance Ω 350 ± 3.5 Insulation Resistance MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 80 Load Cell Weight kg 0.1t – 2.0t: ~ 0.9; 2.5t – 5t: ~ 1.7; 10t: ~ 3.6 Element Material Stainless steel Ingress Protection (acc. to EN 60529) IP67 Recommended Torque on Fixation Bolts Nm M12: 100 M18:200 M24:700 ATEX Classification (optional) II 1G Ex ia IIC T4 Ga II 1D Ex ia IIIC T 200 135°C Da II 3G Ex ic IIC T4 Gc
Stainless steel IP67 single-point load cell
Suitable for weighing equipment like platform and belt scales.
Maximum platform size: 400 x 400 mm
High accuracy.
High reliability.
Current calibrated (SC-option).
Model: B6N Class: C3
Resistance:
Input - 384Ω ± 4Ω Output - 350Ω ± 3.5Ω
Brand: Zemic
Mfg: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
NEA Loadcell (NEA)
Short Description:
Aluminum-alloy IP65 single point load cell
Colourless anodized
Suitable for single and double load cells structured platform scales
Maximum platform size: 600 x 600 mm
A 1000 Ohm type available (R1) but is excluded from OIML
Manufacturer: Yide Sensors Inc.
Origin: Made in Australia
Available Capacity:
Capacity Accuracy Full Article Description 50kg C3 NEA-50kg 100kg C3 NEA-100kg 150kg C3/C4 NEA-150kg 200kg C3/C4 NEA-200kg 250kg C3/C4 NEA-250kg 300kg C3/C4 NEA-300kg 500kg C3/C4 NEA-500kg
Technical Specifications of NEA
Accuracy Class OIML R60 C3, OIML R60 C4 Output Sensitivity ( FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) kg 50, 100, 150, 200, 250, 300, 500, 600; 150, 200, 250, 300, 500, 600 Max. Number of Load Cell Intervals nLC 3000, 4000 Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.02 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.0230; ≤± 0.0175 Minimum dead load Of Emax 0% Safe overload Of Emax 150 % Ultimate Overload Of Emax 300 % Zero balance Of FS ± 2.0 % Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 750±6 Output Resistance Ω 700±3 Insulation Resistance MΩ 5000 (at 50VDC) Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Element Material Aluminum Ingress Protection (acc. to EN 60529) IP65 Recommended Torque on Fixation Bolts Nm M8:25
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6mm
Cable length: 3m
Shield connected to element
Cable jacket in PVC
Wiring Instruction:
Input(Positive) - Red
Output(Positive) - Green
Output(Negative) - Blue
Input(Negative) - Yellow
Used in Single Point Platform, Automated servo belt system, PLC Application, Conveyer system, small floor scale platform
UH62 Loadcell (UH62)
Short Description:
Nickel plated alloy steel IP66 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size:
1. for 50kg-200kg: 400 x 400 mm
2. for 250kg-500kg: 600 x 800 mm
3. for 750kg-2t: 1200 x 1200 mm
Manufacturer: Yide Sensors Inc.
Origin: Made in Australia
Available Models:
Capacity Accuracy Full Article Description 100kg C3 UH62-C3-100kg-3B6 150kg C3 UH62-C3-150kg-3B6 200kg C3 UH62-C3-200kg-3B6 250kg C3 UH62-C3-250kg-3B6 500kg C3 UH62-C3-500kg-3B6 750kg C3 UH62-C3-750kg-3B6 1000kg C3 UH62-C3-1000kg-3B6 2000kg C3 UH62-C3-2000kg-3B6
Technical Specifications of UH62
Accuracy Class C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) Kg 100, 150, 200, 250, 500, 750, 1000, 2000 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / Vmin 7500 Combined Error %FS ≤± 0.020 Minimum dead load Of Emax 0% Safe overload Of Emax 150 % Ultimate overload300 % Of Emax 300 % Zero balance Of FS < ± 1.0 % Excitation, recommended voltage V 5 ~ 12 Excitation maximum V 18 Input Resistance Ω 406 ± 3 Output Resistance Ω 350 ± 3 Insulation Resistance MΩ ≥5000 (at 50VDC) Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP66 Recommended Torque on Fixation Bolts Nm M12:75; M16:200 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6.2mm
Standard cable length: 3m
Shield not connected to element
Wiring Instruction:
Input (Positive) - White
Sense (Positive) - Brown
Output (Positive) - Red
Output (Negative) - Black
Sense (Negative) - Green
Input (Negative) - Yellow
Dimension Wise Capacity:
Dimension Capacity B B1 H H1 H2 L L1 L2 M 50-200kg 44 24 75 50 30 156 112 14 M12 250-500kg 60 36 95 70 30 146 110 11 M12 750kg-2000kg 76 46 125 95 65 176 110 24 M16
Single Point Platform, Automated servo belt system, PLC Application
H6F Load Cell (H6F)
Short Description:
Nickel plated alloy steel IP66 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size:
1. for 50kg-200kg: 400 x 400 mm
2. for 250kg-500kg: 600 x 800 mm
3. for 750kg-2t: 1200 x 1200 mm
Manufacturer: Zemic Europe
Origin: B.V Netherland
Available Models:
Capacity Accuracy Full Article Description 100kg C3 H6F-C3-100kg-3B6 150kg C3 H6F-C3-150kg-3B6 200kg C3 H6F-C3-200kg-3B6 250kg C3 H6F-C3-250kg-3B6 500kg C3 H6F-C3-500kg-3B6 750kg C3 H6F-C3-750kg-3B6 1000kg C3 H6F-C3-1000kg-3B6 2000kg C3 H6F-C3-2000kg-3B6
Technical Specifications of H6F
Accuracy Class C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) Kg 100, 150, 200, 250, 500, 750, 1000, 2000 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / Vmin 7500 Combined Error %FS ≤± 0.020 Minimum dead load Of Emax 0% Safe overload Of Emax 150 % Ultimate overload300 % Of Emax 300 % Zero balance Of FS < ± 1.0 % Excitation, recommended voltage V 5 ~ 12 Excitation maximum V 18 Input Resistance Ω 384 ± 4 Output Resistance Ω 351 ± 2 Insulation Resistance MΩ ≥5000 (at 50VDC) Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP66 Recommended Torque on Fixation Bolts Nm M12:75; M16:200 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6.2mm
Standard cable length: 3m
Shield not connected to element
Wiring Instruction:
Input (Positive) - Red
Sense (Positive) - Brown
Output (Positive) - Blue
Output (Negative) - White
Sense (Negative) - Black
Input (Negative) - Yellow
Dimension Wise Capacity:
Dimension Capacity B B1 H H1 H2 L L1 L2 M 50-200kg 44 24 75 50 30 156 112 14 M12 250-500kg 60 36 95 70 30 146 110 11 M12 750kg-2000kg 76 46 125 95 65 176 110 24 M16
Used in Single Point Platform, Automated servo belt system, PLC Application
H8C Load Cell (H8C)
Short Description:
Nickel plated alloy steel IP67 shear beam load cell
Adhesive sealed
Suitable for platform weighing, bed weighing, etc.
High accuracy
High reliability
Current calibrated (SC-option)
Manufacturer: Zemic Europe
Origin: B.V Netherland
Available Models:
Capacity Accuracy Full Article Description 100kg C3/C4/C5 H8C-C3/C4/C5-100kg-4B(-SC-W6) 250kg C3/C4/C5 H8C-C3/C4/C5-250kg-4B(-SC-W6) 500kg C3/C4/C5 H8C-C3/C4/C5-500kg-4B(-SC-W6) 750kg C3/C4/C5 H8C-C3/C4/C5-750kg-4B(-SC-W6) 1ton C3/C4/C5 H8C-C3/C4/C5-1.0t-4B(-SC-W6) 1.5ton C3/C4/C5 H8C-C3/C4/C5-1.5t-4B(-SC-W6) 2ton C3/C4/C5 H8C-C3/C4/C5-2.0t-4B(-SC-W6) 2.5ton C3/C4/C5 H8C-C3/C4/C5-2.5t-6B(-SC-W6) 3ton C3/C4/C5 H8C-C3/C4/C5-3.0t-6B(-SC-W6) 5ton C3/C4/C5 H8C-C3/C4/C5-5.0t-6B(-SC-W6) 10ton C3/C4/C5 H8C-C3/C4/C5-10t-6B(-SC-W6)
Technical Specifications of H8C
Accuracy Class OIML R60 C3, OIML R60 C4, OIML R60 C5 Output Sensitivity ( FS ) mV/V 3.0 ± 0.003 Maximum Capacity ( Emax ) ton 0.1, 0.25, 0.5, 075, 1, 1.5, 2, 2.5, 3, 5, 10, 01, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 5, 10 Max. Number of Load Cell Intervals nLC 3000, 4000, 5000 Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000, 20000, 18000 Combined Error %FS ≤± 0.023; ≤± 0.0175; ≤± 0.014 Creep Error (30 minutes) %FS ≤± 0.016; ≤± 0.012; ≤± 0.010 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015; ≤± 0.010; ≤± 0.007 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011; ≤± 0.009; ≤± 0.008 Zero balance %FS ≤± 1.0 Safe overload %FS 150 Ultimate Overload %FS 300 Maximum Deflection mm 0.1t – 0.2t: 0.3 0.5t – 5t: ~ 1.2 10t: 0.8 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 350 ± 3.5 Output Resistance Ω 350 ± 3.5 Insulation Resistance MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 80 Load Cell Weight kg 0.1t – 2.0t: ~ 0.9; 2.5t – 5t: ~ 1.7; 10t: ~ 3.6 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP67 Recommended Torque on Fixation Bolts Nm M12: 100 M18:200 M24:700 ATEX Classification (optional) II 1G Ex ia IIC T4 Ga II 1D Ex ia IIIC T 200 135°C Da II 3G Ex ic IIC T4 Gc
Wiring:
Cable type: Shielded, 4 or 6 conductor cable, conductor AWG 22
Cable diameter: Ø 5.0mm
Cable length: 4m for 100kg – 2t; 6m for higher capacities
Shield not connected to element
Wiring Instruction:
For 4 Wire Loadcell:
Input(Positive) - Red
Output(Negative) - White
Input (Negative) - Black
Output(Positive) - GreenFor 6 wire Loadcell:
Input(Positive) - Red
Sense (Positive) - Blue
Output(Negative) - White
Sense (Negative) - Yellow
Input (Negative) - Black
Output(Positive) - Green
Ordering Info:
Example: H8C – C3 – 1.0t – 4 – – BX – SC – XX
H8C Load Cell model C3 Maximum load cell divisions 1.0t Nominal capacity (Emax) for Metric in t (ton) 4 Length of the cable in meters Thread option. No mark is Metric thread and “Y” is Imperial thread BX Cable option. No mark is 4 conductor cable and with a “6” a 6 conductor cable SC Option SC (standard current) XX Option XX. No mark is standard version, W4 is through loading hole, W6 is “T” end loading hole
Used in 4 Point Platform, Hopper Scale, Automated servo belt system, PLC Applications
- 1